The Humidistat Setting

This component continuously monitors the humidity level of the air being expelled through the E·Z Breathe® unit. You can set this control to maintain the desired level of humidity in your home/building.

Humidistat

For best results, set the humidstat between 30 - 50%.

PLEASE NOTE… when the desired humidity level has been achieved, the E·Z Breathe® unit will automatically turn off, and then on again as the humidity level increases. The E·Z Breathe® will run continuously until desired level has been reached. Don't worry; the unit has been designed to perform under these conditions. During winter / colder periods when the furnace is often running, the unit may shut off due to the humidistat reaching the desired humidity level. During these periods, you can set the humidistat to its lowest setting and turn the fan to low. This will cause the unit to run on low continuously, providing ventilation for the space without exhausting heated air.

Fan Speed

Fan Speed Control

The rate at which you expel the air outside is adjustable with the help of this control.

For best results:

  • In the summer, set the speed control on med - high.
  • In the winter, set the speed control to med - low.
  • VENTILATION ONLY: Humidistat to 20% & Fan Speed to slow.

Model 400

Base Dimensions:
Height: 8 inches (20.32cm)
Width: 20 inches (50.8cm)
Depth: 6 inches (15.24cm)
Weight: 16 lbs. (7.3kg)

Chute Dimensions:
Height: Extends up to 102" tall (259.08cm)
Width: 12 inches (30.48cm)
Depth: 2.5 inches (6.35cm)


 